SC Connectorthe push-pull classic of structured cabling
The SC is the optical fibre connector of the telecommunications sector: push-pull locking on the 2.5 mm ceramic ferrule, simplex and duplex, for data centres, LAN cabling per EN 50173 and connections to active components.
- Connector class
- The 2.5 mm classic
- Insertion loss
- 0.20 dB typical
- Mating cycles
- ≥ 1000
- Standardised in
- IEC 61754-4

Official Rosenberger OSI product photography.
The push-pull classic of structured cabling.
SC/APC versions carry the 8° or 9° oblique polished endface, so reflections cannot propagate: the standard choice for singlemode CATV, WDM/DWDM, MAN and WAN plant. Tuning is possible on the spring-mounted ferrule, and the duplex clip assembles two simplex connectors into one footprint.
What the connector brings.
Features
- Single-fibre connector, simplex and duplex
- Push-pull locking mechanism
- Ø 2.5 mm zirconia ceramic ferrule, spring-mounted, centred on slotted sleeve
- PC, UPC and APC 8°/9° polishes
- Tuning possible
- Buffered fibre and cable builds, Ø 0.9 to 3.5 mm
The datasheet, in one view.
Figures are Rosenberger OSI's published values; BASIC and PURE are the two factory quality grades, identified by the part number.
Insertion loss
IL in dB.
Return loss
RL minimum dB.
Mechanical and environmental
Colour coding
Boots in blue, green, black, yellow or red by part number.
Typical applications.
Twelve connectors, one supplier.
Every connector has its own page with the same depth: datasheet specifications, builds, colour coding and applications.
MMCthe VSFF multi-fibre connector12 / 16 / 24 FView 02
MTP®/MPOthe parallel-optics standard, 12 to 72 fibresup to 72 FView 03
LCthe small-form-factor standard, four builds deepsimplex / duplexView 04
MDCVSFF duplex for the MHD generationduplex · 2 FView 05
SN®Senko Nano, the other MHD duplexduplex · 2 FView 06
CS®EZ-Flip duplex with the push-pull tabduplex · 2 FView 07
MUthe first SFF connector, still in servicesimplex / duplexView 08
E-2000®the shuttered connector, up to RL 80 dBsimplex / compactView 09
SCthe push-pull classic of structured cablingsimplex / duplexThis page10
EBO MPEexpanded beam, MTP® footprint, no cleaning12 / 16 F · to 144View 11
EBO Latch 3M™the latch build of the EBO ecosystem12 F · to 144View 12
PRIZM® LightTurn®fibre to the PCB, turned 90° by a lens12 to 48 FView Specifying the connector for a link?
Tell us the fibre type, the panel and the loss budget, and we will confirm the right SC build, quality grade and lead time.