AUTHORIZED PARTNER

Löwenauge Zero-leakage air vents and valves for liquid cooling

German-engineered stainless valves for closed cooling loops: automatic air vents, ball, butterfly, check and safety valves, strainers and flow instrumentation. HeTone distributes and supports the range across Asia.

Brand Overview

Löwenauge Industry combines German engineering, from its office in Erlangen, with production in China, focused on one discipline: precise control of closed piping systems with zero-leakage technology. The company is ISO 9001:2015 certified and its Greater China operations centre ships within 30 days.

The brand made its name on automatic air-vent valves for liquid cooling. The VAC 71 side-exhaust series is presented as the first stainless-steel air vent developed specifically for data-center CDUs: a dry-closure design keeps coolant away from the vent opening so it cannot clog, and a rotation-resistant float keeps venting reliable even on vibrating equipment such as wind turbines.

Around the vents sits a complete stainless valve programme for CDU and rack-level cooling loops: full-bore and mini ball valves, interlocking and quick-connect variants, butterfly valves to DN200, low-cracking-pressure check valves, 300-mesh Y-strainers, resetting safety valves, and flow instrumentation up to an IO-Link electromagnetic flowmeter.

16 barWorking pressure across the valve range
0.2 barAir-vent opening pressure
-40 – 150 °CMedia temperatures covered
ISO 9001Certified, delivery within 30 days
Product Series

Featured product families.

Ball Valves

Full-bore stainless ball valves from mini G1/8 CDU sizes through quick-connect straight and Tri-Clamp three-way variants to mechanically interlocked versions, all rated 16 bar with PTFE zero-leakage seats.

16 bar · 316L

Butterfly Valves

Flanged DN50 to DN200 stainless butterfly valves with EPDM or Viton seats and bubble-tight shutoff, operated manually, pneumatically or electrically for CDU and facility mains.

DN50 – DN200

Check Valves

316L and 304 check valves that open below 0.05 bar, sealing with EPDM, FKM or PTFE across threaded, flanged and Tri-Clamp connections to protect CDU and manifold circuits from backflow.

Opens ≤ 0.05 bar

Y-Strainers

Stainless Y-strainers with a removable 300-mesh, 48 µm screen and a flow area two to three times the pipe section, catching weld slag and debris before it reaches pumps and cold plates.

300 mesh · PN10

Automatic Air Vents

The Löwenauge speciality: VAC 71 side-exhaust and VA 73 top-exhaust vents release trapped air and microbubbles continuously, with a dry closure that keeps coolant off the opening.

Vents at 0.2 bar

Safety Valves

Spring safety valves in copper or stainless steel with relief settings from 2.5 to 10 bar and precise reseating after the event, protecting CDU and rack loops from overpressure.

2.5 – 10 bar relief

Flow Sensors

Stainless flow sensors covering 0.9 to 240 L/min with frequency and pulse outputs for continuous coolant flow monitoring across DN8 to DN32 lines.

0.9 – 240 L/min

Electromagnetic Flowmeter

A compact all-in-one magmeter, DN6 to DN65, with PEEK liner, ±0.5% accuracy and IO-Link or Modbus RTU connectivity for precision loop measurement.

±0.5 % accuracy
The speciality

Air out, coolant in, nothing leaks.

Trapped air and microbubbles cut cooling efficiency and can overheat hardware. Löwenauge air vents release them continuously, and the dry-closure principle means coolant never touches the vent opening, so it cannot clog or weep.

Dry closureCoolant never reaches the opening: 100% clog-free venting over the system lifetime.
Rotation-resistant floatKeeps sealing under vibration, proven on wind-turbine installations as well as CDUs.
Zero-leakage guaranteePrecision machining to leak-free tolerances, helium-tested stainless bodies.
Microbubbles collect above the coolant; the float meters them out through the dry vent.
Tap X-ray to look inside Löwenauge VAC 71 side-exhaust air vent VAC 71 cutaway render showing float and dry closure
VAC 71Side exhaust

The first stainless air vent developed specifically for data-center CDUs. Side-exit venting for tight manifold spaces, with check-valve and ball-valve variants.

SUS 316L / 304 16 bar Vents at 0.2 bar -40 – 115 °C G3/8
Tap X-ray to look inside Löwenauge VA 73 top-exhaust air vent VA 73 cutaway render showing float and dry closure
VA 73Top exhaust

Vertical venting for the highest point of the loop, where air naturally collects. Stainless or nickel-plated copper bodies, with ball-valve service variants.

SUS 316L / 304 / CW617N 16 bar Vents at 0.2 bar -40 – 115 °C G3/8
VAC 71 side-exhaust series, 6 models
ModelBodyMax. pressureVent opensTemperatureConnection
VAC 71SUS 316L16 bar0.2 – 0.5 bar-40 – 115 °CG3/8
VAC 71-ZSUS 316L16 bar0.2 – 0.5 bar-40 – 115 °CWith check valve R3/8 · R1/2 · G1/2
VAC 71-BSUS 316L16 bar0.2 bar-40 – 115 °CWith ball valve G3/8 · G1/2
VACI 71SUS 30416 bar0.2 bar-40 – 115 °CG3/8
VACI 71-ZSUS 30416 bar0.2 bar-40 – 115 °CWith check valve R3/8 · R1/2 · G1/2
VACI 71-BSUS 30416 bar0.2 bar-40 – 115 °CWith ball valve G3/8 · G1/2
VA 73 top-exhaust series, 6 models
ModelBodyMax. pressureVent opensTemperatureConnection
VA 73SUS 316L16 bar0.2 bar-40 – 115 °CG3/8
VAI 73SUS 30416 bar0.2 bar-40 – 115 °CG3/8
VA 73-BSUS 316L16 bar0.2 bar-40 – 115 °CWith ball valve G3/8 · G1/2
Nickel-plated copper VAT 73CW617N16 bar0.2 bar-30 – 115 °CG3/8
VAT 73-ZCW617N16 bar0.2 bar-30 – 115 °CWith check valve R3/8 · R1/2 · G1/2
VAT 73-BCW617N16 bar0.2 bar-30 – 115 °CWith ball valve G3/8 · G1/2
Valve programme

See the products. Tap for the specs.

Every shutoff, protection and filtration point of a CDU or rack cooling loop, in 304 and 316L stainless with zero-leakage seats, shown in official product photos.

Tap any product to see its full specifications

Stainless steel ball valve

Stainless Steel Ball Valve

Full-bore shutoff for CDU, manifold and AI-server cooling loops. Tri-Clamp and weld-end three-piece bodies in 316L for easy in-line service.

316LBody material
16 barWorking pressure
-40 – 120 °CTemperature
PTFEZero-leakage seats
Full boreThree-piece bodyCDU & manifold loops
Mini stainless steel ball valve

Mini Ball Valve, KBV series

Ultra-compact shutoff for high-density CDU layouts and sensor lines. Machined to DIN EN ISO 2768-1, every valve helium-tested to a leak rate under 2 grams per year.

SUS304 / 316LBody material
G1/8 – G1/2Connections
16 barWorking pressure
< 2 g/yrHelium-tested leakage
100% helium testedGlycol & DI waterMultiple connection types
Quick-connect straight ball valve

Quick-Connect Straight Ball Valve

Shutoff and quick coupling in one body: connect or open a line in seconds during installation and service, without draining the loop.

304 / 316LBody material
16 barWorking pressure
-20 – 120 °CTemperature
Fast service connectionsStraight-way flow
Quick-connect three-way ball valve

Quick-Connect Three-Way Ball Valve

Tri-Clamp three-way routing with a no-dead-leg design that keeps coolant clean and flow resistance low — built for modular data-center deployment.

304 / 316LBody material
16 barWorking pressure
Tri-ClampConnection
No dead-legLow flow resistanceModular deployment
Interlocking ball valve

Interlocking Ball Valve

A mechanical interlock physically prevents mis-operation on critical loops — the valve cannot be opened or closed out of sequence.

316LBody material
16 barWorking pressure
-40 – 120 °CTemperature
Mechanical interlockFail-safe critical loops
Stainless butterfly valve

Stainless Butterfly Valve

Bubble-tight shutoff for CDU and facility mains from DN50 to DN200, operated manually, pneumatically or electrically.

304 / 316LBody material
DN50 – DN200Sizes, flanged
10 barWorking pressure
EPDM / VitonSeat options
Manual / pneumatic / electricFacility mains
Stainless check valve

Stainless Check Valve

Backflow protection that opens below 0.05 bar, so it costs the pump almost nothing. Threaded, flanged and Tri-Clamp connections protect CDU and manifold circuits.

316L (CF8M) / 304Body material
16 / 25 barWorking pressure
≤ 0.05 barOpening pressure
-40 – 150 °CTemperature
EPDM / FKM / PTFEThread / flange / Tri-Clamp
Stainless Y-filter

Stainless Y-Filter

Catches weld slag and debris before it reaches pumps and cold plates. The removable 300-mesh screen has a flow area two to three times the pipe section, so pressure drop stays low.

316 / 316LBody material
300 mesh / 48 µmRemovable screen
PN10Pressure rating
-10 – 100 °CTemperature
Flow area 2–3× pipeDIN 11850 / DIN 32676
VS320 safety valve

Safety Valve, VS series

Spring safety valves that relieve overpressure and reseat precisely after the event. VS320 in stainless for CDU and rack loops; VS311/VS312 in copper for general industrial circuits.

SUS304 / 316LVS320 body
2.5 – 10 barRelief range
-40 – 110 °CTemperature
8 fixed settings2.5 / 3 / 3.5 / 4 / 5 / 6 / 8 / 10 bar
Automatic reseatSettings 2.5 – 10 barCopper variants VS311/312
Mini ball valve models, KBV series
ModelMaterialConnectionPressureRecommended for
KBV-304-M08SUS304G1/816 barMiniature sensor lines
KBV-316-M10SUS316LG1/416 barCorrosive environments
KBV-304-M12SUS304G3/816 barStandard CDU applications
KBV-316-M15SUS316LG1/216 barHigh-performance cooling loops
Instrumentation

Measure what you cool.

From simple pulse sensors to a billing-grade electromagnetic meter with digital connectivity.

Löwenauge electromagnetic flowmeter

Electromagnetic flowmeter

Size
DN6 – DN65
Accuracy
±0.5 %
Turndown
1:150
Liner / electrodes
PEEK · 316L / Hastelloy C
Media temperature
-40 – +125 °C
Outputs
4–20 mA · pulse · IO-Link · RS-485
Protection
IP65 / IP67

Stainless flow sensor

Pulse-output turbine sensing for continuous coolant monitoring, in stainless across six line sizes.

0.9 – 240 L/minRange
DN8 – DN32Size
-40 – +125 °CTemperature
Frequency / pulseOutput
Stainless steelBody
Water, glycol mixesMedia
Key Models

Representative models we stock.

These are selected highlight SKUs, contact us for the full catalogue and custom cut sizes.

ModelTypeKey SpecApplication
SS Ball Valve Ball Valve 316L, 16 bar, -40 – 120 °C CDU, manifold and rack loops
KBV Mini Series Ball Valve G1/8 – G1/2, He-tested < 2 g/yr Sensor lines, compact CDU layouts
Quick-Connect Straight Ball Valve 304/316L, 16 bar Fast service connections
Quick-Connect 3-Way Ball Valve Tri-Clamp, low dead-leg Modular data-center deployment
Interlocking Ball Valve Ball Valve Mechanical interlock, 316L Fail-safe critical loops
SS Butterfly Valve Butterfly Valve DN50 – 200, 10 bar CDU and facility mains
SS Check Valve Check Valve Opens ≤ 0.05 bar, 16/25 bar Backflow protection at CDUs
SS Y-Strainer Strainer 300 mesh / 48 µm, PN10 Debris capture ahead of pumps
Applications

Where Löwenauge products are used.

Speccing vents or valves for a cooling loop?

Tell us your loop pressures, media and connection standards, and we will map the right Löwenauge vents, valves and instrumentation, with samples and local support from HeTone.