Solstice® 454B
The most optimized R-410A replacement: matching capacity, improved efficiency and minimal redesign for precision cooling and reversible heat pumps.
Five Solstice® fluids cover a data centre's whole cooling duty: room and precision air conditioning, air- and water-cooled chillers, heat pumps and two-phase liquid cooling on cold plates. HeTone supplies the range across Asia with safety-class guidance and selection support.
Honeywell Solstice® refrigerants are engineered for the room and precision air conditioning that data centres run on - and as chips grow hotter and denser, two-phase liquid cooling on Solstice fluids delivers uniform cooling with better heat rejection and lower pumping power. The range spans two ASHRAE safety classes: A2L where codes accept mildly flammable equipment and efficiency leads the specification, and nonflammable A1 where the safety case rules flammability out.
Each of the five fluids is positioned against a refrigerant the industry already runs. Solstice 454B replaces R-410A with matching capacity and a GWP 78% lower; ze, N15 and 513A give three exit paths from R-134a at three GWP levels; and zd replaces R-123 in low-pressure centrifugal chillers at a GWP of 1. Published GWP values run from 631 down to below 1 on the IPCC AR5 basis.
Solstice Advanced Materials was created through the 2025 spin-off of Honeywell's Advanced Materials business - the same fluorine chemistry, manufacturing network and Solstice platform, now a dedicated company. HeTone distributes the refrigerant range across Asia, from fluid selection and safety-class guidance through datasheets, SDS documentation and supply.
Filter by ASHRAE class and the range narrows to match. GWP values are Solstice’s published IPCC AR5 figures.

The most optimized R-410A replacement: matching capacity, improved efficiency and minimal redesign for precision cooling and reversible heat pumps.

Ultra-low-GWP, energy-efficient alternative to R-134a for the air-cooled and water-cooled chillers and heat pumps that carry a data centre's base load.

Nonflammable with a GWP of 1: better capacity and similar efficiency to R-123 in low-pressure centrifugal chillers and high-temperature heat pumps.

A nonflammable azeotropic blend that matches R-1234ze capacity and efficiency, so it drops straight into any system designed around R-1234ze.

A zero-glide, nonflammable R-134a replacement approved by major equipment makers: matching capacity and efficiency with no system redesign.
Solstice 454B and Solstice ze, mildly flammable per ASHRAE 34. The choice where codes already accept A2L equipment and energy efficiency leads the spec.
2 fluids · GWP 467 / <1Solstice zd, N15 and 513A carry Class A1 for safety cases that rule out flammability, from centrifugal chillers to drop-in R-134a service.
3 fluids · GWP 1-631Room and precision air conditioning, air- and water-cooled chillers, heat pumps, and two-phase liquid cooling on cold plates.
AC · chillers · cold platesAll five fluids plotted against the same axis, using Solstice’s published AR5 values. Two of them barely register — that is the point.
GWP = Global Warming Potential, IPCC 5th Assessment Report basis, as published on each Solstice product page. Reduction claims (−78% vs R-410A, −56% / −77% vs R-134a) are Solstice’s own figures.
Published typical properties from each Solstice product page — physical data, temperature limits, safety and approvals. Pick a fluid.
Typical properties as published by Solstice Advanced Materials on each product page; not a specification. For engineering design, request the full technical datasheet and SDS through HeTone.
Every fluid in the range is positioned against an incumbent. Pick yours and the answer follows.
Solstice 454B is Solstice's most optimized R-410A replacement: matching capacity, improved efficiency and a GWP 78% lower, with minimal changes from an R-410A design.
Three paths, by safety class and GWP target: ze (A2L, GWP <1) for the lowest footprint, N15 (A1, GWP 293) where nonflammability is required, and 513A (A1, GWP 631) for zero-glide drop-in service.
Solstice zd is the nonflammable, GWP-1 replacement for R-123, with better capacity and similar efficiency in centrifugal chillers and high-temperature heat pumps.
Solstice N15 matches the capacity and efficiency of R-1234ze, so it can be used in all equipment that has been designed for R-1234ze - while moving the safety class to nonflammable A1.
Solstice Advanced Materials was created through the 2025 spin-off of Honeywell’s Advanced Materials business — the same fluorine chemistry, plants and Solstice® platform the industry has run on for a decade, now a dedicated company. HeTone supplies the range across Asia with selection, documentation and SDS support.
Measured values from our application engineering materials. Contact us for complete datasheets and lot-specific certificates.
| Fluid | ASHRAE No. | Type | Replaces | GWPAR5 | ClassASHRAE 34 | Glide | Lubricant |
|---|---|---|---|---|---|---|---|
| Solstice 454B | R-454B | Zeotropic blend | R-410A | 467 | A2L | 1.5 | POE |
| Solstice ze | R-1234ze | Pure fluid (HFO) | R-134a | <1 | A2L | 0 | POE |
| Solstice zd | R-1233zd | Pure fluid (HFO) | R-123 | 1 | A1 | 0 | Mineral oil |
| Solstice N15 | R-515B | Azeotropic blend | R-134a | 293 | A1 | 0 | POE |
| Solstice 513A | R-513A | Azeotropic blend | R-134a | 631 | A1 | 0 | POE |
Values from HeTone application engineering materials, request official datasheets for design sign-off.
Send the equipment type, the refrigerant you run today and the safety class your site allows, and we will confirm the right Solstice fluid, documentation and availability.