HYDRONIC BALANCING

IMI TA-Smart balance, control and measure in one valve

A balancing and control valve for heating and cooling that also meters the circuit it sits in. Flow, valve position, supply and return temperatures, temperature difference, power and energy are measured continuously and reported over BLE, bus, analog or cloud, so the loop stops being something you infer from a design sheet. Threaded DN 15-50 and flanged DN 65-150.

IMI TA-Smart products
Brand Overview

TA-Smart is built around three principles: control, measurement and communication. It controls to flow, to power or to valve position, and a ΔT limitation function can be added to any of those control types, including at part load. It measures flow, valve position, return and supply temperatures, temperature difference, power and energy, continuously rather than at a commissioning visit. And it communicates and stores that data over BLE, bus, analog and cloud, with full digital configuration from the HyTune mobile app or the web app.

The valve comes in two ranges. DN 15-50 is a threaded two-body build with only four fittings to mount and no straight-pipe requirement upstream, and it carries the secondary temperature sensor in its own external housing. DN 65-150 is flanged to the F1 face-to-face length of EN 558-1, with the remote temperature sensor fitted separately. HeTone supplies TA-Smart alongside the pumps, piping, bellows, quick disconnects and leak detection that surround it, so the balancing point is specified with the rest of the loop rather than sourced on its own.

Product Series

Featured product families.

Control

Versatility of valve control modes operating according to flow, power and valve position, with outstanding controllability. A ΔT limitation function can be added to any of the control types, even in part-load system conditions.

Flow · power · position

Measurement

Continuous measurement of flow, valve position, return and supply temperatures, temperature difference, power and energy. Nothing has to be inferred from a design sheet or a one-off commissioning reading.

Six measured quantities

Communication

Communicates and stores over BLE, bus, analog and cloud, and is fully digitally configurable through the HyTune mobile app and the web app.

BLE · bus · analog · cloud
Valve Construction

Every part, and the job it does.

The two ranges are built around the same idea. They differ in the body, the actuator, and how the second temperature sensor is mounted. Select a numbered point to read what it does.

IMI TA-Smart DN 15-50 balancing and control valve with SmartBox, actuator, measuring section and external temperature housing
IMI TA-Smart DN 65-150 flanged balancing and control valve with orange actuator and SmartBox
In Depth

A closer look.

TA-Smart Fail-safe valves, threaded DN 15-50 and flanged DN 65-150

Supercapacitors hold the position when the power goes

TA-Smart Fail-safe is powered by supercapacitors and drives the valve to a fail-safe position when supply is lost. With the delay option the actuator waits for the number of seconds you configure before moving, so a brief fluctuation does not become a valve movement, and the transition when it does happen is smooth rather than abrupt.

  • Supercapacitor-backed fail-safe positioning
  • Configurable delay before the actuator moves
  • Smooth transition to the fail-safe position
TA-Smart DN 15-50 fitted with its insulation shells

Insulation shells, and a body that fits

Insulation shells are available for heating and non-condensing cooling applications. On DN 15-50 the valve is a two-body build with only four fittings to mount and no straight-pipe requirement upstream, which is what makes it viable in a riser cupboard or a crowded plant room where a conventional balancing and control pair would not go.

  • Insulation shells for heating and non-condensing cooling
  • Two bodies, only four fittings to mount
  • 0D requirement upstream
Differential Pressure Control

TA-Smart-Dp holds the pressure across the circuit.

The Dp variant gives the dual advantage of maintaining stable differential pressure in a circuit while still delivering the energy and operating data. It senses the pressure on the supply side and at the valve itself, and modulates to keep the difference between them steady as the load moves.

Δp = p₁ − p₂ held steady as the load moves SUPPLY RETURN p₁ p₂ Δp = p₁ − p₂ as the load moves held steady SUPPLY RETURN p₁ p₂

← Swipe to see the whole diagram →

Static pressure range · pressure modules

TA-Sense-Dp-6

0 – 6 bar

TA-Sense-Dp-10

0 – 10 bar

TA-Sense-Dp-16

0 – 16 bar

TA-Sense-Dp-25

0 – 25 bar

Pick the module for the circuit's static pressure. Inside that, the differential pressure range is adjusted continuously from the buttons on the valve or from the HyTune app. TA-Smart-Dp runs DN 15-150, takes BACnet or Modbus in, and gives BACnet, Modbus or 0(2)-10 VDC out. On DN 65-150 the flange-to-flange length matches the STAP and TA-PILOT-R mechanical differential pressure controllers, so it replaces one in place.

Reduced Size & Weight

Eleven sizes on one scale.

Face-to-face length across the whole range, drawn against a single millimetre axis. DN 15-50 is measured as L1 on the threaded body, DN 65-150 as the F1 length to EN 558-1.

DN mm
DN 15-50Threaded
15 167 DN 15 · 167 × 165 mm · G3/4 · W 97 mm
20 180 DN 20 · 180 × 166 mm · G1 · W 97 mm
25 187 DN 25 · 187 × 166 mm · G1 1/4 · W 97 mm
32 200 DN 32 · 200 × 191 mm · G1 1/2 · W 97 mm
40 218 DN 40 · 218 × 190 mm · G2 · W 97 mm
50 239 DN 50 · 239 × 190 mm · G2 1/2 · W 97 mm
DN 65-150Flanged F1
65 290 DN 65 · 290 × 377 mm · Ø 185 mm · 4 / 8 bolts
80 310 DN 80 · 310 × 380 mm · Ø 200 mm · 8 bolts
100 350 DN 100 · 350 × 438 mm · Ø 220 / 235 mm · 8 bolts
125 400 DN 125 · 400 × 444 mm · Ø 250 / 270 mm · 8 bolts
150 480 DN 150 · 480 × 462 mm · Ø 285 / 300 mm · 8 bolts
Face-to-face length (mm) Hover a bar for height and connection

“Very compact, up to 80% smaller than competitors' product.”

DN 15-50 · IMI TA-Smart brochure, p. 16

“Compact F1 length, up to 30% smaller than competitor's product.”

DN 65-150 · IMI TA-Smart brochure, p. 16

Application Types

Where TA-Smart is applied.

Secondary / tertiary circuit control

Air handling units

Heat exchangers

CRAH units

Benefits At Every Stage

From drawing board to retrofit.

1 Design 2 Installation 3 Commissioning 4 Operation 5 Renovation
Time savings Energy efficiency Certifications Flexibility of use Peace of mind Comfort
Product Data

Representative product data.

Measured values from our application engineering materials. Contact us for complete datasheets and lot-specific certificates.

TA-Smart DN 15-50 · dimensions

DN D L1mm Hmm Wmm
15 G3/4 167 165 97
20 G1 180 166 97
25 G1 1/4 187 166 97
32 G1 1/2 200 191 97
40 G2 218 190 97
50 G2 1/2 239 190 97

Values from HeTone application engineering materials, request official datasheets for design sign-off.

TA-Smart DN 65-150 · dimensions

DN Ø D PN16mm Ø D PN25mm Bolts PN16 Bolts PN25 Lmm Hmm
65 185 185 4 8 290 377
80 200 200 8 8 310 380
100 220 235 8 8 350 438
125 250 270 8 8 400 444
150 285 300 8 8 480 462

Values from HeTone application engineering materials, request official datasheets for design sign-off.

Applications

Where IMI products are used.

Size a TA-Smart for your circuit

Send us the duty, the differential pressure and the connection you are working to. We will come back with the size, the variant and the control mode that fit, from the same team that supplies the pumps, piping and leak detection around the valve.