Automatic float vents
Five ROBOCAL bodies and three MINICAL bodies cover the 1.75 SCFM class across NPT and straight-thread connections, with or without a service check valve underneath.
1.75 SCFMAir is the failure a closed loop hides best: the flow still reads nominal while a pocket at the high point starves the pump or blankets a cold plate. Caleffi's air vents are the component that takes it back out, on their own, with no power and no signal. Seven series, from a 1.75 SCFM ROBOCAL on a manifold to a 9 SCFM MAXCAL on the main.
Caleffi builds float-type automatic air vents for closed hydronic circuits, and the same physics applies to a liquid-cooling loop: air comes in at fill, arrives with make-up water and comes out of solution as the coolant warms, then migrates to whatever point sits highest. The range on this page covers four discharge classes, 1.75 SCFM on ROBOCAL and MINICAL, 2.5 SCFM on VALCAL, 4.5 SCFM on DISCALAIR and 9 SCFM on MAXCAL, plus the HYGROCAL emitter vent and a manual vent. Bodies are brass, working pressure runs to 150 psi (10 bar) and 230 psi (16 bar) on the MAXCAL, with medium temperatures to 250 °F (120 °C).
HeTone supplies these vents into the same loop as its pumps, piping, stainless bellows, quick disconnects and leak detection, so the deaeration point gets specified with the rest of the circuit instead of being added afterwards. Every part number on this page carries Caleffi's published tender text and, where the manufacturer issues one, its SCIP code. DWG, DXF, STEP, IGES and BIM files come with the quotation.
Five ROBOCAL bodies and three MINICAL bodies cover the 1.75 SCFM class across NPT and straight-thread connections, with or without a service check valve underneath.
1.75 SCFMVALCAL at 2.5 SCFM, DISCALAIR that keeps venting all the way up to 150 psi instead of stalling, and MAXCAL at 9 SCFM on a 230 psi body for large mains.
up to 9 SCFMHYGROCAL vents on its own through a hygroscopic cartridge and opens by hand at the knob. The 337 manual vent has a metal seal and an adjustable outlet for commissioning bleeds.
Auto or manualHow it works
There is no electronics inside a Caleffi air vent, and nothing to commission. The coolant level does the sensing and the float does the switching. Step through it below.
It goes at the high point. Air in a closed loop always ends up wherever the piping is highest, so that is where the vent belongs: the top of a riser, a manifold, the crown above a pump. Everything below it stays full of coolant.
Cavitation at the pump
Air drawn into the impeller collapses against the vanes. You hear it before you measure it, and the wear does not undo itself.
Heat that never leaves
An air pocket against a cold plate is an insulator. The flow meter still reads nominal while the junction temperature climbs.
Oxygen in the loop
Air brings oxygen, and oxygen attacks the metal it sits against. Venting it out is the cheapest corrosion control in the system.
Selection
Seven series, four capacity classes. Pick the rate the point needs, then the body and connection that fits it. Every figure below is Caleffi's own published data.
Float-type automatic vent for the points where air collects: manifolds, pump inlets, the top of a riser. Five bodies cover NPT and straight-thread connections, with or without a service check valve.
Same 1.75 SCFM discharge in a smaller brass body, rated to 250 °F. Choose the plain vent, the check-valve version for swap-outs, or the anti-drip cap where a stray drop would land on something expensive.
When 1.75 SCFM is not enough. Both bodies ship with the hygroscopic safety cap, and the 5023 doubles as the replacement vent for 548-series hydraulic separators.
The only vent here whose discharge pressure equals its working pressure: it keeps venting at 150 psi instead of stalling. Stainless steel float guide pin and linkage, 3/4" male and 1/2" female connections on one body.
Five times the ROBOCAL's discharge rate, 230 psi working pressure and a −4 °F floor. Sized for large mains and system high points, with a 3/8" female top thread so the discharge can be piped away.
A chrome-finished emitter vent that works either way: it vents on its own through a cellulose-fibre cartridge that swells shut on contact with water, and it opens by hand when you turn the knob. The cartridge is a replaceable part.
No float, no cartridge. A metal-seal manual vent with an adjustable outlet, for commissioning bleeds and the points where you would rather nothing opened on its own.

The 5027, 5021 and 5023 bodies carry a service check valve underneath the vent. Unscrew the vent, the check valve holds the system closed, fit the replacement, walk away. On a populated rack that one detail is the difference between a five-minute job and a drain-down.

The hygroscopic safety cap holds cellulose-fibre discs that grow by half their volume the moment they meet water, closing the discharge within seconds. Caleffi is explicit that this is a safety device rather than an airtight seal, so pressure testing means swapping the cap for a plain plastic one or fitting an isolation valve below the vent. The discs biodegrade, and the cap is a three-year replacement item.

MAXCAL discharges five times the ROBOCAL rate on a 230 psi body, with a stainless steel float guide pin and linkage and a −4 °F floor. The 3/8" female top thread means the discharge can be piped away instead of dripping onto whatever sits below it.
Specification
The line you paste into a specification, exactly as Caleffi publishes it. Open a series, open a part number, copy the text. Or search and go straight to it.
20 part numbers
CALEFFI, 502610A, ROBOCAL™. Automatic air vent connection: 1/8" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 90 psi. Medium temperature range: 32 – 240 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP code0f42c99e-8e30-4cf9-9c3b-77e437b149f4
CALEFFI, 502620A, ROBOCAL™. Automatic air vent connection: 1/4" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 90 psi. Medium temperature range: 32 – 240 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP code6f5a7bf9-be40-4967-ae11-c9173ead96d9
CALEFFI, 502710A, ROBOCAL™. Automatic air vent with service check valve connection: 1/8" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 90 psi. Medium temperature range: 32 – 230 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP coded7192d51-bd43-46c7-85f9-8ff04bd7f688
CALEFFI, 502720A, ROBOCAL™. Automatic air vent with service check valve connection: 1/4" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 90 psi. Medium temperature range: 32 – 230 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP code66112de2-2deb-40d0-9dfb-c3eae7ff1a82
CALEFFI, NA502740A, ROBOCAL™. Automatic air vent with service check valve/hygroscopic cap connection: 1/2" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 90 psi. Medium temperature range: 32 – 230. Maximum discharge rate: 1.75 SCFM. Material: brass.
CALEFFI, 502420, ROBOCAL. Automatic air vent (1⁄4" straight thread) connection: 1/4" straight thread M. Maximum operating pressure: 10 bar. Maximum air discharge pressure: 4 bar. Medium temperature range: 0–115 °C. Material: brass.
SCIP code4bc0cf28-b3ea-47ab-a904-3e28e4bb3d02
CALEFFI, 502630, ROBOCAL. Automatic air vent (⅜"-½" straight thread) connection: 3/8" straight thread M. Maximum operating pressure: 10 bar. Maximum air discharge pressure: 6 bar. Medium temperature range: 0–115 °C. Material: brass.
SCIP code0ff4d6ec-7dd9-47c3-b4dc-ac3e6fb686c6
CALEFFI, 502640, ROBOCAL. Automatic air vent (⅜"-½" straight thread) connection: 1/2" straight thread M. Maximum operating pressure: 10 bar. Maximum air discharge pressure: 6 bar. Medium temperature range: 0–115 °C. Material: brass.
SCIP coded9e23f8a-5b4c-43da-b18c-e48816c66a41
CALEFFI, 502015A, MINICAL. Automatic air vent connection: 1/8" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 40 psi. Medium temperature range: 32 – 250 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP coded02ad069-ca1b-4a8b-8ffc-a2af3ee6632f
CALEFFI, 502040A, MINICAL. Automatic air vent connection: 1/2" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 40 psi. Medium temperature range: 32 – 250 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP code016a7d3f-9779-4235-96a2-88732ece6e93
CALEFFI, 502115A, MINICAL. Automatic air vent with service check valve connection: 1/8" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 40 psi. Medium temperature range: 32 – 230 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP code85ca73cc-3785-4217-8815-b16dd8121b2f
CALEFFI, 502113A, MINICAL. Automatic air vent with service check valve connection: 1/8" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 40 psi. Medium temperature range: 32 – 230 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
CALEFFI, 502043A, MINICAL. Automatic air vent with anti-drip cap Hygroscopic safety air vent cap connection: 1/2" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 40 psi. Medium temperature range: 32 – 250 °F. Maximum discharge rate: 1.75 SCFM. Material: brass.
SCIP code35b04267-5663-436b-84d3-db6c18a80cdf
CALEFFI, 502243A, VALCAL™. High discharge automatic air vent Hygroscopic safety air vent cap connection: 1/2" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 60 psi. Medium temperature range: 32 – 250 °F. Maximum discharge rate: 2.5 SCFM. Material: brass.
SCIP code2adb27c8-ff84-47a1-98d6-100a8fb57e86
CALEFFI, 502343A, VALCAL™. High discharge automatic air vent with service check valve Hygroscopic safety air vent cap Replacement air vent for union 548 hydro separators connection: 1/2" NPT male. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 60 psi. Medium temperature range: 32 – 230 °F. Maximum discharge rate: 2.5 SCFM. Material: brass.
SCIP codea8d2eb97-b1f3-4fe5-9658-a87f0442ca2f
CALEFFI, 551004A, DISCALAIR®. High discharge automatic air vent Stainless steel float guide pin and linkage connection: 3/4" NPT male. connection: 1/2" NPT female. Maximum operating pressure: 150 psi. Maximum air discharge pressure: 150 psi. Medium temperature range: 32 – 230 °F. Maximum discharge rate: 4.5 SCFM. Material: brass.
SCIP coded8d60454-6e27-422d-9b30-8812a4e6f934
CALEFFI, 501502A, MAXCAL™. Extra high capacity automatic air vent Stainless steel float guide pin and linkage Discharge top thread: ⅜" female straight thread Replacement air vent for NA548 and NA549 hydro separators connection: 3/4" NPT female. Maximum operating pressure: 230 psi. Maximum air discharge pressure: 90 psi. Medium temperature range: -4 – 250 °F. Maximum discharge rate: 9 SCFM. Material: brass.
SCIP codeb510cfd2-db56-4766-bf06-7e9142155809
CALEFFI, 508013A, HYGROCAL™. Automatic/manual hygroscopic air vent Manually operated by rotating knob Priced each, sold in quantities of 25 connection: 1/8" NPT male. Maximum operating pressure: 150 psi. Medium temperature range: 40 – 212 °F. Finish: Chrome. Material: brass.
SCIP codecc0fa87f-2501-46f4-8d6a-141725dabe79
CALEFFI, 508100A. Replacement hygroscopic cartridge Fits 5080 HYGROCAL™ Priced each, sold in quantities of 25
SCIP code46723c83-d061-4e11-bd76-5bfdafd6e114
CALEFFI, 337221A. Manual air vent Metal seal and adjustable outlet. connection: 1/4" NPT male. Maximum operating pressure: 150 psi. Medium temperature range: 40 – 212 °F. Material: composite/brass.
No part number matches that search.
Drawings and 3D models. DWG, DXF, STEP, IGES and BIM files exist for most of these part numbers. Tell us which ones your drawing set needs and we will send them with the quotation.
Figures are Caleffi's published product data. Metric equivalents are Caleffi's own where the manufacturer publishes them, and converted otherwise. Confirm the current revision against the datasheet before it goes into a released drawing.
Imperial figures are Caleffi's published product data, with the manufacturer's own metric equivalents alongside. Connection, tender text and SCIP code for every individual part number are further down this page.
| Model | Type | Key Spec | Application |
|---|---|---|---|
| ROBOCAL™ | Automatic, 5 bodies | 1.75 SCFM · 150 psi · 32–240 °F | Manifolds, pump inlets, risers |
| MINICAL® | Automatic, 3 bodies | 1.75 SCFM · 150 psi · 32–250 °F | Tight spaces, anti-drip points |
| VALCAL™ | High discharge, 2 bodies | 2.5 SCFM · 150 psi · 32–250 °F | Separators, larger branches |
| DISCALAIR® | High discharge, 1 body | 4.5 SCFM · vents at 150 psi | Points that must vent under pressure |
| MAXCAL™ | Extra high capacity | 9 SCFM · 230 psi · −4–250 °F | Large mains, system high points |
| HYGROCAL™ | Automatic or manual | 150 psi · 40–212 °F · chrome | Emitters and terminal units |
| Manual | Manual, metal seal | 150 psi · 40–212 °F | Commissioning bleeds |
Send us the loop layout and where the high points sit. We will come back with part numbers, the tender text for your specification and the drawing files your set needs, from the same team that supplies the pumps, piping and leak detection around them.